TONOMETERS AT-A-GLANCE

0
TONOMETER TYPE MEASUREMENT RANGE METHOD BENEFITS
BICOM Inc. | 877.342.8667 | TonometerDiaton.com
DIATON Handheld, scleral/
transpalpebral

5-60 mmHg

Non-contact
(No corneal
contact)
• No corneal contact; IOP measured through the eyelid and sclera, so reading is CCT independent
• Can take reading with patient in seated or supine positions
• No sterilization or replacement covers required
Icare | 888.422.7313 | Icare-USA.com
Icare HOME Handheld 5-50 mmHg Patented
rebound
technology
• EyeSmart automatic OD/OS recognition technology
• EasyPos intelligent positioning assistant
• AMS automatic measuring sequence
• Series and single mode with one button
Icare ic100 Handheld 7-50 mmHg Patented
rebound
technology
• AMS automatic measuring sequence; series and single mode with one button
• EasyNav advanced navigation interface
• EasyPos intelligent positioning assistant
Icare TAO1 Handheld 7-50 mmHg Patented
rebound
technology
• No calibration and no anesthetic necessary
• Quick and easy IOP screening
• Lightweight probe makes quick, gentle contact with the cornea
Keeler | 800.523.5620 | KeelerUSA.com
AccuPen Handheld 5-60 mmHg Contact tip
• Gravity Offset Technology provides precise measurements with less calibration
• Sighting lines for easy visualization of the cornea
• Contoured molding with a large, visible LCD, enabling ambidextrous use
• Takes fast measurements with patient in any position
D-KAT
Digital “R”
Type
Slit lamp
mounted
0-80 mmHg Applanation
Tonometer
• Allows visualization of the measurement in an LED screen for darkened environments
• Fits most upper illumination slit lamps
• Also comes in non-digital version
D-KAT
Digital “T”
Type
Slit lamp
mounted
“” Applanation
Tonometer
• Allows visualization of the measurement in an LED screen for darkened environments
• Also comes in non-digital version
D-KAT
Digital “Z”
Type
Slit lamp
mounted
“” Applanation
Tonometer
• Allows visualization of the measurement in an LED screen for darkened environments
• Fits all lower illumination slit lamps
Pulsair
Desktop
Tabletop 5-50 mmHg Air Puff • Puff automatically adjusts for the next measurement in patients with high readings
• Takes average of four readings to 0.1 mmHg
Pulsair
IntelliPuff
Handheld
5-50 mmHg Air Puff • Puff automatically adjusts for the next measurement in patients with high readings
• Takes average of four readings to 0.1 mmHg
• Wall mounting available
Marco | 800.874.5274 | Marco.com
AT-9
Slit lamp mounted
0-80 mmHg Applanation
tonometer
• Check weight and check weight holder
• Two measuring prisms standard
• Smoother rotation and operation for accurate positioning and approach at the patient cornea
M3 TONOREF II ARK & Non-
Contact
Tonometer
Tabletop 1-60 mmHg Air Puff • Three-in-one device: non-contact tonometer, autorefractor and autokeratometer
• Completely automatic, using three axes: alignment, tracking and focus
• Automatic Pressure Control for a softer air puff
OCULUS, Inc. | 425.670.9977 | OculusUSA.com
Corvus STL
Tabletop 6-60 mmHg
Air Puff
Non-contact
Tonometry and
Pachymetry
• Video of air puff with visualization
• Provides 4300 frames/second with high speed camera
• Takes optical pachymetry measurements
Reichert | 888.849.8955 | Reichert.com
Ocular
Response
Analyzer G3
Tabletop 1-60 mmHg
Air Puff
• Measures corneal hysteresis
• Provides IOPcc: IOP compensated for corneal biomechanics
Tono-Pen AVIA Handheld 5-50 mmHg
Contact tip • Portable
• Uses average of 10 different readings
• IOP measurements that are less sensitive to corneal centration
PT100 Handheld 0-60 mmHg
Air Puff • Portable, non-contact
• Uses average of 3 readings
• Comes complete with charging base and carrying case
Reichert 7CR Tabletop 1-60 mmHg Air Puff • Provides IOPcc: IOP compensated for corneal biomechanics
Tomey | 888.449.4045 | TomeyUSA.com
FT-1000 Tabletop 0-60 mmHg
Non-contact • Touch screen alignment
• Auto alignment and auto shot
• Corneal thickness related IOP
Share.