TONOMETERS AT-A-GLANCE

0
TONOMETER TYPE MEASUREMENT
RANGE

METHOD BENEFITS
Accutome  |  800.979.2020  |  accutome.com  |  info@accutome.com
AccuPen Handheld 5-60 mmHg Contact tip
•Gravity Offset Technology provides precise measurements with less calibration
•Takes average of 9 readings and accounts for corneal thickness
•No fluorescein required
•Inexpensive AccuTip disposable tip covers
BICOM Inc.  |  877.342.8667  |  tonometerdiaton.com  |  contact@tonometerdiaton.com
DIATON Handheld

5-60 mmHg

Non-contact
(No corneal
contact)
•Takes measurement through the eyelid and sclera
•Can take reading in seated or supine positions
•No sterilization or replacement covers required
Icare  |  888.422.7313  | icare-usa.com  |  info@icare-usa.com
Icare ic100
Handheld 7-50 mmHg Patented
rebound
technology
•AMS automatic measuring sequence; series and single mode with one button
•EasyNav advanced navigation interface
•EasyPos intelligent positioning assistant
Icare TAO1i Handheld 7-50 mmHg Patented
rebound
technology
•No calibration and no anesthetic necessary
•Quick and easy IOP screening
•Lightweight probe makes quick, gentle contact with the cornea
Keeler  |  800.523.5620  | keelerusa.com
Pulsair
Desktop
Tabletop 5-50 mmHg Air Puff •Puff automatically adjusts for the next measurement in patients with high readings
•Takes average of 4 readings to 0.1º
Pulsair
IntelliPuff
Handheld/
Tabletop
5-50 mmHg Air Puff •Puff automatically adjusts for the next measurement in patients with high readings
•Takes average of 4 readings to 0.1 degree
•Wall mounting available
D-KAT
Digital “R”
Type
Slitlamp
mounted
0-80 mmHg Applanation
Tonometer
“¢ Allows visualization of the measurement in an LED screen for darken environments
“¢ Fits most Upper Illumination Slitlamps
“¢ Also comes in non-digital version
D-KAT
Digital “T”
Type
Slitlamp
mounted
“” Applanation
Tonometer
“¢ Allows visualization of the measurement in an LED screen for darken environments
“¢ Also comes in non-digital version
D-KAT
Digital “Z”
Type
Slitlamp
mounted
“” Applanation
Tonometer
•Allows visualization of the measurement in an LED screen for darken environments
•Fits all lower illumination slitlamps
Marco  |  800.874.5274  | marco.com
M3 Tabletop 1-60 mmHg Air Puff •Three-in-one device: non-contact tonometer, autorefractor and autokeratometer
•Completely automatic, using three axes: alignment, tracking and focus
•Automatic Pressure Control for a softer air puff
OCULUS, Inc.  |  425.670.9977  |  oculusausa.com  |  sales@oculusausa.com
Corvus STL
Tabletop 1-60 mmHg
Air Puff
Non-contact
Tonometry and
Pachymetry
•Video of air puff with visualization
•Provides 4330 frames/second with high speed camera
•Takes optical pachymetry measurements
Reichert  |  888.849.8955  |  reichert.com
Ocular
Response
Analyzer G3
Tabletop 1-60 mmHg
Air Puff
•Measures corneal hysteresis
•Provides Corneal Compensated Intraocular Pressure
•Softer, quieter puff
Tono-Pen AVIA Handheld  5-50 mmHg
Contact tip •Portable
•Uses average of 10 different readings
•IOP measurements that are less sensitive to corneal centration
PT100 Handheld 0-60 mmHg
Air Puff •Portable, non-contact
•Uses average of 3 readings
•Comes complete with charging base and carrying case
Reichert 7CR Tabletop 1-60 mmHg Air Puff •Provides Corneal Compensated Intraocular Pressure
•Softer, quieter puff
Tomey  |  888.449.4045  | tomeyusa.com
FT-100 Tabletop 0-60 mmHg
Non-contact •Touch screen alignment
•Auto alignment and auto shot
•Corneal thickness related IOP
Share.